1.1.8 Upper Cover
1. Turn off the main switch and unplug the power supply cord.
2. Remove the platen cover or DF.
3. Remove the left side scale [A] (2 screws).
4. Remove the exposure glass [B]. (See Exposure Glass Removal.)
5. Remove the operation panel [C] from the upper cover (2 screws and 2
connectors).
6. Remove the upper cover [D] with the operation panel (8 screws).
[B]
[A]
[D]
[C]
A219R500-3.wmf
Replacement
Adjustment
20 December 1996 EXTERIOR AND INNER COVERS
6-3