CODE #55 — FUSING ERROR 4
- Definition -
The temperature value output by the thermistor has not changed at all
16 (NA) or 20 (EU) seconds after the main switch is turned on.
The temperature change detected by the thermistor is more than 20°C
within any one second after the 16 (NA) or 20 (EU) seconds warm up
time after the main switch is turned on.
To clear this error, refer to note 3 at the beginning of this chapter.
- Possible Causes -
Thermistor open
Defective main control board
Defective ac drive/dc power supply board
Fusing lamp open
Poor thermistor connection
SERVICE CALL CONDITIONS 20 December 1996