2) Image Density Adjustment Factor (SP34)
Depending on the SP34 setting, the development bias and the exposure
lamp settings are increased or decreased during ADS mode.
SP34 Setting Setting Dev. Bias Exposure Lamp
0Normal0 0
1 Light –40 V 0
2 Dark +40 V 0
3 Lightest –40 V +4 steps
4 Darkest +40 V –4 steps
1 step = 0.5 V (120 V machines) or 1.0 V (230 V machines)
3) Manual Image Density Setting Factor
Depending on the manual image density setting on the operation panel, the
exposure lamp voltage is changed as shown in the table below:
Manual ID
Level
1234567
Exposure
Lamp Voltage
Factor
V
0
– 6
steps
V
0
– 4
steps
V
0
– 2
steps
V
0
V
0
+ 2
steps
V
0
+ 6
steps
V
0
+ 12
steps
Development
Bias Voltage
(Volts)
–200 –200 –200 –200 –200 –240 –240
V
0
: Base lamp voltage setting (SP48)
1 step = 0.5 V (120 V machines) or 1.0 V (230 V machines)
LighterDarker
OPTICS 20 December 1996
2-12