Laser Optics 
SM 3-21 G133 
Replacement 
Adjustment 
1.  Plug in and turn on the main power switch. 
 
2.  Adjust the main scan magnification only for black (Bk). 
  Input the standard value [A] provided with a new laser optics housing unit for the 
main scan magnification adjustment with SP2-185-001. 
 
  The value [A] is different for each laser optics housing unit. 
  Print the test pattern (14: 1-dot trimming pattern in the SP2-109-003). 
  Check that the left and right trim margin is within 4 ± 1 mm. If not, change the 
standard value for the main scan magnification adjustment. 
3.  Adjust the main scan registration only for black (Bk). 
  Input the registration value [B] provided with a new laser optics housing unit for the 
main scan registration adjustment with SP2101-001. 
 
  The value [B] is different for each laser optics housing unit. 
  Print the test pattern (14: 1-dot trimming pattern in the SP2-109-003). 
  Check that the left trim margin is within 2 ± 1 mm. If not, change the registration 
value for the main scan registration adjustment. 
4.  Select "0" with SP2-109-003 after printing the "1-dot trimming pattern. 
5.  Do the line position adjustment. 
  First do SP2-111-3.   
  Then do SP2-111-1. 
To check if SP 2-111-1 was successful, watch the screen during the process. A 
message is displayed at the end. Also, you can check the result with SP 2-194-10 
to -12. 
6.  Exit the SP mode. 
7.  After you replace the housing unit, do the adjustments in the following section of the