EasyManua.ls Logo

Ricoh G133 - Blown Fuse Conditions; Power Supply Unit

Ricoh G133
993 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical Component Defects
G133 4-102 SM
No.
Sensor Name/
Sensor Board Name
Active CN Condition Symptom
S8
Ferrite Roller HP
Sensor
L CN224/7
Open/
Shorted
SC549
S7 Fusing Belt Sensor H/L CN225/2
Open/
Shorted
SC584
S14
Junction Gate 1 HP
Sensor
L C215/B12
Open/
Shorted
SC529
S3 Junction Paper Jam L C232/7
Open/
Shorted
Jam C (Jam 24/64)
4.6.2 BLOWN FUSE CONDITIONS
Power Supply Unit
R: This means that it is possible to replace in the field (for example: Tube fuse).
Rating
Fuse
115V
220V -
240V
Symptom when turning on the main
switch
Remark
FU1 15A/125V 8A/250V
No response. (The main power to the PSU is
not supplied.)
R
FU2 10A/125V 6.3A/250V
No response. (The main power to the PSU is
not supplied.)
R
FU3 2A/250V 1A/250V
5V power to the scanner heater and tray
heater is not supplied.
-
FU4 1A/250V 1A/250V
5V power to the IOB and heater is not
supplied.
-
FU5 5A/250V 5A/250V 5V power to the IOB not supplied. -
FU6 2A/250V 2A/125V 5VS power to the EGB not supplied. -

Table of Contents