Process Control Error Conditions
G133 4-6 SM
No. Result Description Possible Causes Action
connection.
Replace the IOB
board.
3
ID sensor
output error
ID sensor output
is more than
"Voffset
Threshold"
(SP3-324-004)
1. Defective ID sensor
2. Poor connection
3. Defective IOB
Replace the ID
sensor.
Check the
connection.
Replace the IOB
board.
9
Vsg
Adjustment
error
Vsg adjustment
has not been
completed.
Other cases
Retry the
SP3-321-010.
4.1.3 LINE POSITION ADJUSTMENT RESULT
SP2-194-010 to -012 (Line Position Adjustment Result: M, C, Y)
This SP shows the number as a line position adjustment result on the LCD. It shows which
color has an error (M, Y or C).
No. Result Description Note
0 Not done Line position adjustment has not been done. -
1
Completed
successfully
Line position adjustment has correctly been
done,
-
2
Cannot detect
patterns
ID sensors have not detected the patterns for
line position adjustment.
See Note
3
Fewer lines on
the pattern than
the target
The patterns, which ID sensors has detected,
are not enough for line position adjustment.
See Note
4
More lines on
the pattern than
Not used in this machine. -