Electrical Component Defects
SM 4-103 G133
Trouble-
shooting
Rating
Fuse
115V
220V -
240V
Symptom when turning on the main
switch
Remark
FU7 10A/125V 10A/125V 24VS power to the IOB not supplied. R
FU8 10A/125V 10A/125V 24VS power to the IOB not supplied. R
FU9 6.3A/125V 6.3A/125V 24V power to the IOB not supplied. R
FU10 6.3A/125V 6.3A/125V Not used R
FU11 6.3A/125V 6.3A/125V 24V power to the EGB not supplied. R
FU12 6.3A/125V 6.3A/125V 24V power to the PFU or LCT not supplied. R
FU13 6.3A/125V 6.3A/125V 24V power to the finisher not supplied. R
FU14 5A/250V 5A/250V 5V power to the EGB not supplied. -
IH Inverter
Rating
Fuse
115V 220V - 240V
Symptom when turning on the main switch
FU1 15A/125V 8A/250V
15V power to the IH coil unit is not supplied.
SC689 occurs.
FU2 115°C No response
FU3 115°C No response
FU4 1A/250V
15V power to the IH coil unit is not supplied.
SC689 occurs.
For continued protection against risk of fire, replace only with same type and rating
of fuse.