SC Table
SM 4-15 G133
Trouble-
shooting
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE ON error: Bk
The PFGATE ON signal does not assert within 5 seconds after
processing the image in normal job or MUSIC for start position [K].
Defective ASIC (Lupus)
Poor connection between controller and EGB.
Defective EGB
230 D
1. Check the connection between the controller board and the EGB.
2. Replace the EGB.
3. Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE OFF error: Bk
The PFGATE ON signal still asserts within 5 seconds after
processing the image in normal job or MUSIC for end position [K].
The PFGATE ON signal still asserts when the next job starts.
231 D
See SC 230 for troubleshooting details.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE ON error: Y
The PFGATE ON signal does not assert within 5 seconds after
processing the image in normal job or MUSIC for start position [Y].
232 D
See SC 230 for troubleshooting details.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE OFF error: Y 233 D
The PFGATE ON signal still asserts within 5 seconds after