SC Table
G133 4-36 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Motor overload
Defective fusing/paper exit motor
Replace the fusing/paper exit motor.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Heating roller thermopile error
The temperature measured by the heating roller thermopile does not
reach 0°C for 6 seconds.
Loose connection of the heating roller thermopile
Defective heating roller thermopile
Defective thermopile
541 A
1. Check if the heating roller thermopile is firmly connected.
2. Replace the heating roller thermopile.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Heating roller warm-up error 1
The heating roller temperature does not reach the ready
temperature for 190 seconds after the IH inverter turns on.
The heating roller temperature does not reach 80°C for 18 seconds
after the IH inverter on.
Dirty or defective thermopile
Defective IH coil unit
542 A
1. Check if the heating roller thermopile is firmly connected.
2. Replace the thermopile.
3. Replace the IH coil unit.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)