EasyManua.ls Logo

Ricoh G133 - Page 262

Ricoh G133
993 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC Table
G133 4-46 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
1. Replace the IH inverter.
2. Replace the EGB.
3. Replace the IOB.
4. Check the connection between IH inverter and IOB.
5. Replace the thermopile.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
IH coil unit rare short error
The IH inverter detects an unusual current (high current) in the IH coil
unit.
Defective IH coil unit
Defective IH inverter
586 D
1. Replace the IH coil unit.
2. Replace the IH inverter.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
IH inverter high temperature error
The IH inverter detects a high temperature near Q5 (power control
circuit on the IH inverter).
Defective IH inverter
Defective IH inverter fan
Clogged IH inverter fan intake at the right rear cover
Incorrect input paper type to the machine
587 D
1. Check or clean the IH inverter fan intake.
2. Set the correct paper type on the operation panel.
3. Replace the IH inverter.
4. Replace the IH inverter fan.

Table of Contents