SC Table
G133 4-64 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Defective controller
- -
1. Check that the HDD is correctly connected to the controller.
2. Replace the HDD.
3. Replace the controller.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
823
CTL
B
Self-diagnostic error: NIB
[XXXX]: Detailed error code
[6101]
MAC address check sum error
The result of the MAC address check sum does not match the check
sum stored in ROM.
[6104]
PHY IC error
The PHY IC on the controller cannot be correctly recognized.
[6105]
PHY IC loop-back error
An error occurred during the loop-back test for the PHY IC on the
controller.
- 1. Replace the controller.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
[1401]
Self-diagnosis error: Standard NVRAM
The controller cannot recognize the standard NVRAM installed or
detects that the NVRAM is defective.
Loose connection
Defective standard NVRAM
Defective controller
824
CTL
D
1. Check the standard NVRAM is firmly inserted into the socket.
2. Replace the NVRAM.