Troubleshooting Guide
SM 4-81 G133
Trouble-
shooting
After Executing SP2-111-003
Bk 2. Replace the laser optics housing
unit.
3. Replace the EGB.
Others
Skew correction upper limit error
Defective EGB
Defective laser optics housing unit
1. Replace the EGB.
2. Replace the laser optics housing
unit.
Result:
"0"
- - Do SP2-111-001 or -002.
After Executing SP2-111-001
Result (SP2-194)
-007
-010, -011,
-012
Test pattern check Possible cause/Countermeasure
White image,
Abnormal image,
Low density
Defective laser optics housing unit
shutter
Defective image processing unit
Low density of test pattern
Defective EGB
1. Replace the shutter motor.
2. Replace the high voltage power
supply unit.
3. Do the forced process control
(SP3-011-001) or supply some
toner (SP3-015-xxx).
4. Replace the EGB.
Result:
"1"
Result:
"2" or "3"
(Line pattern
detection
failure)
Normal image, but
with color registration
Defective ID sensor shutter
Defective ID sensor