Troubleshooting Guide
SM 4-83 G133
Trouble-
shooting
After Executing SP2-111-001
The skew for M, C, Y
is more than ± 0.75
mm from the main
scan registration of
Bk. – at the end of
the scan line?
Defective PCU
Defective laser optics housing unit
Defective EGB
1. Reinstall or replace the PCU.
2. Replace the laser optics housing
unit.
3. Replace the EGB.
Others
Skew correction upper limit error
Defective EGB
Defective laser optics housing unit
1. Replace the EGB.
2. Replace the laser optics housing
unit.
The main scan
registration of Bk is
shifted.
Abnormal SP setting value of
main scan: Bk
1. Adjust the value with
SP2-101-001.
No color
registration
errors
The main scan
length of Bk is
shifted.
Abnormal SP setting value of
main scan length detection: Bk
1. Adjust the value with
SP2-185-001.
Low image density
on the output
Low pattern density
1. Do the forced process control
(SP3-011-001) or supply some
toner (SP3-015-xxx).
Result:
"0"
Color
registration
errors
The main scan
registration is shifted,
but only at the
central area of the
image on the output.
Defective ID sensor at center
Deformed center area on the
image transfer belt
Defective EGB
1. Replace the ID sensor.
2. Replace the image transfer belt.