Service Mode Table
G133 5-46 SM
Front, Center, Rear: ID sensors for the automatic line position adjustment
001 Maximum 2: Bk *ENG
002 Maximum 2: M *ENG
003 Maximum 2: C *ENG
004 Maximum 2: Y *ENG
005 Maximum 2: Front *ENG
006 Maximum 2: Center *ENG
007 Maximum 2: Rear *ENG
[0 to 5.5 / 0 / 0.01V/step]
[ID Sensor Check Result] DFU
2145
Displays the minimum result 2 values of the ID sensor check.
Bk, M, C, Y: ID sensors for the process control
Front, Center, Rear: ID sensors for the automatic line position adjustment
001 Minimum 2: Bk *ENG
002 Minimum 2: M *ENG
003 Minimum 2: C *ENG
004 Minimum 2: Y *ENG
005 Minimum 2: Front *ENG
006 Minimum 2: Center *ENG
007 Minimum 2: Rear *ENG
[0 to 5.5 / 0 / 0.01V/step]
[Area Mag. Correction] LD Pulse Area Correction (Area, Color) FA
2150
Adjusts the magnification for each area. The main scan (297 mm) is divided
into 8 areas. Area 1 is at the front side of the machine (left side of the image)
and area 8 is at the rear side of the machine (right side of the image).
Decreasing a value makes the image shift to the left side on the print.