Service Mode Table
G133 5-178 SM
3321 [Vsg Adjustment: Execution]
010 P/TM Sensor All -
Execute the ID sensor initialization setting
for all sensors
[Vsg Adjustment Result: Vsg]
3322
Displays the result value of the Vsg adjustment for each sensor.
001 Vsg reg: Bk *ENG
002 Vsg reg: M *ENG
003 Vsg reg: C *ENG
004 Vsg reg: Y *ENG
[0 to 5.5 / - / 0.01 V/step]
005 Vsg dif: M *ENG
006 Vsg dif: C *ENG
007 Vsg dif: Y *ENG
[0 to 5.5 / - / 0.01 V/step]
008 Vsg TM (Front) *ENG
009 Vsg TM (Center) *ENG
010 Vsg TM (Rear) *ENG
[0 to 5.5 / - / 0.01 V/step]
3323 [Vsg Adjustment Result: Ifsg] DFU
001 Ifsg: Bk *ENG
002 Ifsg: M *ENG
003 Ifsg: C *ENG
004 Ifsg: Y *ENG
[0 to 50 / - / 0.1 mA/step]
005 Ifsg TM (Front) *ENG
006 Ifsg TM (Center) *ENG
[0 to 50 / - / 0.1 mA/step]