Service Mode Table
G133 5-212 SM
This SP displays the external RCG installation status.
0: External RCG not registered
1: External RCG registered
2: Device registered
Connect Mode (N/M)
023
This SP displays and selects the embedded RCG connection method.
[0 or 1 / 0 / 1 /step
0: Internet connection
1: Dial-up connection
061
Cert. Expire Timing DFU
Proximity of the expiration of the certification.
062 HTTP Proxy Use
This SP setting determines if the proxy server is
used when the machine communicates with the
service center.
HTTP Proxy Host
063
This SP sets the address of the proxy server used for communication
between embedded RCG-N and the gateway. Use this SP to set up or display
the customer proxy server address. The address is necessary to set up
embedded RCG-N.
The address display is limited to 128 characters. Characters beyond
the 128 character are ignored.
This address is customer information and is not printed in the SMC
report.
HTTP Proxy Port
064
This SP sets the port number of the proxy server used for communication
between embedded RCG-N and the gateway. This setting is necessary to set
up embedded RCG-N.
This port number is customer information and is not printed in the
SMC report.
065 HTTP Proxy Aut Usr

Table of Contents