PERFORMER Digital Partyline, User Manual, Version 2.30
Settings
DIP SW 6 ON CH A ready for GPI Out
DIP SW 7 ON CH B ready for GPI Out
DIP SW 8 OFF GPI Out by CALL
4.2.9 GPI (Momentary)
Activating the GPI key (function key block) closes all GPI Out relay contacts (local & partyline)
associated with the active (TALK = ON) digital partyline channels.
Note: The GPI Out relay contact of a unit closes onl, if the related DIP switches of this unit are
set (
Æ
prerequisite).
Selection GPI Key
GPI active Yellow 100%
GPI inactive (default mode) Yellow 10%
Settings
DIP SW 6 ON CH A ready for GPI Out
DIP SW 7 ON CH B ready for GPI Out
DIP SW 8 ON GPI Out by GPI
4.2.10 M/Kill (Momentary)
Activating M/KILL (function key block) mutes all microphones on the active (TALK = ON)
digital partyline channels. The microphone of the local CD-2 stays active.
Note: Disable the M/KILL function with the related DIP 3 switch.
Setting M/Kill Key
M/KILL active Red 100%, 1,5 seconds
M/KILL inactive (default mode) Red 10%
M/KILL OFF – inactive Red 10%
M/KILL OFF – active Red 100%, 1,5 seconds
Setting
DIP SW 3 OFF M/KILL mode enabled