EasyManua.ls Logo

Riedel Performer C44plus - SA Stage Announcement (Momentary); M;MUTE (Latching); PGM Level Control

Riedel Performer C44plus
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PERFORMER Digital Partyline, User Manual, Version 2.30
4.2.11 SA Stage Announcement (Momentary)
With an active SA (function key block) the microphone signal is routed to the SA output (local
4W) and the related GPI Out relay contact closes (Æ Pin Out D-Sub).
Selection SA Key
SA active Yellow 100%
SA inactive Yellow 10%
4.2.12 M/MUTE (Latching)
Activating M/MUTE (function key block) mutes all active TALKS of the unit.
While M/MUTE is active, TALKS can be pre-selected / deselected by pressing the related
TALK key. A pre-selcted but muted TALK key flashes slowly.
Note: The microphone of the CD-2 stays active for the stage announcement SA (local 4W).
Selection M/MUTE Key
M/MUTE active Red 100%
M/MUTE inactive Red 10%
TALK Key
“Active” TALK key - muted Red 100% slow flashing
“Inactive” TALK key - muted Red 10%
4.2.13 PGM Level Control
The PGM (program) rotary encoder adjusts the listen volume (0-100%) of the PGM input
(local 4W) of the unit. Turn the encoder clockwise to increase and counterclockwise to
decrease the volume of the program input. The PGM volume is MUTED when the encoder is
turned counterclockwise as far as it will go.
Adjust the PGM level input with the screw-adjustment of the back of the unit.
This PGM input is not routed to the partylines!
Note: Pushing the rotary encoder currently has no function (for future optional use).