12 TROUBLESHOOTING
Problem Cause Solution
C3 / CW-2 Error LED flickers.
A defective cable or the
maximum cable length has
been exceeded.
Check cable.
Check cable length.
Device does not start. A defective cable or the
maximum cable length has
been exceeded. Too little
voltage on the line.
Check cable.
Check cable length.
Check power.
Crackles and static on the
partyline.
A defective cable or the
maximum cable length has
been exceeded. Too little
voltage on the line.
Check cable.
Check cable length.
Check power.
Audio is not loud enough in
the headset.
Wrong microphone
configuration for headset
(dynamic/electret
microphone).
Check what kind of
microphone you are using
(dynamic/electret) and set
the DIP switch on the C3
beltpack to the correct
value.
No audio signal is present
on the analog audio I/Os of
the C44 in stand-alone
mode.
Incorrect DIP switch
settings.
Check DIP switch settings
(see Chapter 5).