PERFORMER Digital Partyline, User Manual, Version 2.30
Problem Cause Solution
No audio signal from the
intercom matrix to the
partyline.
Incorrect configuration of
the intercom matrix.
Check configuration of the
intercom system (Director).
Check the cable from the
matrix to the partyline.
The partyline is set-up
correctly and connected to
the matrix but the partyline
does not start.
Incorrect firmware in the
matrix.
Please check the firmware
and contact Riedel
Customer Service.
The C3 cannot talk on the
partyline.
DIP switches 3 and 4 are in
the ON position. With this
setting of the DIP switches
the partyline cannot be
spoken on.
Check DIP switches 3 and 4.
Turn OFF if necessary.
The C3 cannot talk or listen. DIP switch 8 is in the ON
position. The beltpack is in
side tone mode.
Check DIP switch 8 and turn
OFF if necessary.