Chapter 13 Store and Recall    RIGOL 
MSO4000/DS4000 User’s Guide  13-5 
To Perform Internal Storage and Recall 
 
The internal memory supports the storage and recall of setup files, reference 
waveform files and pass/fail test mask files. In the following section, the internal 
storage and recall method and procedures are introduced by taking the setup file as 
an example. 
 
1.  Save the specified oscilloscope setting in internal memory 
1)  Connect the signal to the oscilloscope and set the related parameters to 
obtain stable display. 
2)  Press Storage  Storage; turn the multi-function knob   to select 
“Setups” and press the knob. You can also press Storage continuously to 
switch to “Setups”. 
3)  Press Save to turn on the disk management interface. Turn the 
multi-function knob 
 to select “Local Disk” (the characters turn green) 
and press down the knob to open the local disk storage interface (as shwon 
in Figure 13-1). 
4)  The local disk can store at most 10 setup files. Turn the multi-function knob 
 to select the desired storage location and Save becomes available; then 
press the softkey to execute the saving operation. If the current location 
contains a file, you can press Save  OK to directly overwrite the original 
file or press Delete to delete the file.  
 
Figure 13-1 Local Disk (Storage) 
 