PACK 5040M/6050M
PACK 5040A/6050A
Every
40
hours.
Air filtering
unit.
Cleaning. Clean with a
blast of air and
alcohol.
See 40 "Filter
cleaning".
Every
40
hours.
Welding wire. Cleaning. Use a clean, dry
(non-abrasive)
cloth.
-
Every
40
hours.
T
eflon fabric. Cleaning. Use a clean, dry
(non-abrasive)
cloth.
-
Every
200
hours.
T
urbine impeller. Cleaning. Use a cloth or
compressed air.
-
Every
200
hours.
Drive belts. General
inspection.
Check tension and
adjust, if
necessary,
adjust.
See "Transmission
belts
adjustment".
Every
200
hours.
Conveyor belt. General
inspection.
Check tension and
adjust, if
necessary,
adjust.
See “conveyor
belt adjustment”.
Every
200
hours.
T
unnel carrier. General
inspection.
Check tension and
adjust, if
necessary,
adjust.
See "Tunnel
carrier
adjustment".
Every
200
hours.
Cutting thread. General
inspection.
Check for wear
and, if
necessary,
replace.
See "Replacing
the welding
wire".
Every
200
hours.
T
eflon fabric. General
inspection.
Check for wear
and, if
necessary,
replace.
See "Replacement
of Teflon
fabric".
Every
1000
hours.
Carrier guide. General
inspection.
Lubricate. See “Lubrication
point diagram”.
Every
1000
hours.
Safety devices. Check efficiency. Have any faulty
device replaced.
Contact the
technical
assistance
service.
| Note
T
he maintenance
p
eriods relate to 8 -hour workin
g
da
y
s.
|
Important
To protect the machine, during long periods of inactivity, remove it from the mains voltage, remove the
compressed air and empty the condensation collection cup, on the FR unit of the pressure regulator.
Protect the entire machine, b
y
coverin
g
it with suitable material, to
p
revent the accumulation of dust.