PACK 5040M/6050M
PACK 5040A/6050A
7. MAINTENANCE INFORMATION
7.1. MAINTENANCE INSTRUCTIONS
‒ Before performing any operation, the authorised operator must make sure that he/she understood the
"Instructions for use".
‒ Pay attention to the SAFETY WARNINGS, do not use the machine for UNSPECIFIED PURPOSES and assess
the
ossible RESIDUAL RISKS.
‒ Carr
out the interventions with all the safet
devices enabled and wear the DPI
rovided.
‒ DO NOT carry out any intervention that is not described in the manual but contact an Assistance Service
authorised b
the manufacturer.
‒ DO NOT damp in the environment materials, pollutant liquids and the residues created during the
interventions but dis
ose them accordin
to the standards in force.
i
Danger - Warning
Before performing any maintenance operation, activate all of the security devices provided and evaluate the
necessit
to ade
uatel
inform
ersonnel o
eratin
in the near vicinit
.
In particular, confine the neighbouring areas to impede access to the devices that could, if activated, produce
unex
ected dan
er conditions
rovokin
hazards to
ersonal safet
and health.
i
Danger - Warning
Maintenance operations must only be performed with the machine disconnected from the electrical and
pneumatic power supplies.
By regularly checking the working of a number of the more important parts of the machine, subsequent
roblems can be avoided, and the machine can be ke
t in
erfect workin
order.
herefore, carr
out the followin
monthl
checks
‒ no oil or
rease leaks out from the reduction units
‒ there is no excessive blacklash in the chains, belts and their respective tighteners and that they have
not stretched to an
si
nificant de
ree
‒ Dust and dirt de
osits in movin
arts do not hinder their movement
‒
he belts must not dis
la
si
ns of lateral fra
in
or wear of the fabric.
7.2. ROUTINE MAINTENANCE INTERVALS
| Important
Keep the machinery in maximum efficiency condition and perform all the scheduled maintenance operations
provided for by the manufacturer.
Proper maintenance will provide the best performance, a longer life span and constant compliance with safety
requirements.
Maintenance period table
Freque‑
ncy
Component Type of
intervention
Procedure Reference
Every
40
hours.
Machine. General
inspection.
Clean with a
cloth of air jet.
-
Every
40
hours.
Air filtering
unit.
Condensation
control.
Condensation
discharging.
See “Condensate
drainage”.
English