PACK 5040M/6050M
PACK 5040A/6050A
| Note
If shrink tunnel temperature is more than 100°C when the key is pressed, the cooling procedure will start
until tem
p
erature lowers less than 100°C.
2.
T
urn the
g
eneral (A) switch to the "O" (OFF)
p
osition to turn off the
p
ower su
pp
l
y
.
6.8. EMERGENCY STOP AND RESTART
1. Turn main switch (A) on "O" (OFF) in conditions of imminent risk.
Machine o
p
eration sto
p
s immediatel
y
.
2. Remove the
p
roduct from inside the tunnel.
3. After having normalized the working conditions, rotate main switch on "I" (ON) to allow machine
o
p
eration.
4. Re
p
eat all the start-u
p
o
p
erations to restart the c
y
cle.
6.9. REEL LOADING
Depending on the (B) width and the (H) height
of the product to be packaged, choose the
appropriate film spool according to the
following formula: L = B + H + 50 mm
Example H = 80 mm, B = 200 mm
L ≥ 200+80+50
L ≥330 mm