PACK 5040M/6050M
PACK 5040A/6050A
8. TROUBLESHOOTING
8.1. ALARM MESSAGES
In the event of a breakdown during operations the machine stops automatically and alarm messages appear
on the dis
la
.
he table lists the dis
la
ed messa
es, the t
e of
roblem, the cause and
ossible solutions.
|
Important
For these operations a precise technical skill or ability is required; therefore, these operations must be
exclusivel
erformed b
ualified
ersonnel with certified ex
erience ac
uired in the s
ecific field.
Alarms List
Name Pack M Pack A Problem Cause Remedy
E00 x x Initial message,
waiting for
pressure heating
start.
Machine power-on. Press the Start
Heating button.
E10 x Emergency welder. Sensitive edge of
the welder
activated by the
presence of an
obstacle under
the welder.
Remove the
obstacle and
press the Start
Heating button.
E20 x x Magnetothermal
turbine engine.
Magnetothermal
relay protected.
Eliminate the
cause of the
overload,
reactivate the
protection with
the appropriate
reset and press
the Start Heating
button.
E40 x x Writing error in
eeprom.
Problem in the
CPU.
Carry out
resetting of
parameters to
default values.
E50 x x
unnel
temperature too
high (>210°C).
A temperature of
more than 210°C
is measured in
the tunnel.
Allow the tunnel
to cool down to
less than 200°C
temperature.
E70 x "Waiting between
two cycles"
button not
enabled pressed,
due to manual
machine.
Type of manual
machine.
Release the
button.
English