2F-85 & 2F-140 - Instruction Manual
l
0x08 - Maximum operating temperature exceeded ( 85 °C internally), let cool down (below 80 °C).
l
0x09 No communication during at least 1 second.
Major faults(LED blinking red/blue) - Reset isrequired (rising edge on activation bit (rACT) needed).
l
0x0A - Under minimum operating voltage.
l
0x0B - Automatic release in progress.
l
0x0C - Internal fault; contact support@robotiq.com.
l
0x0D - Activation fault, verify that no interference or other error occurred.
l
0x0E - Overcurrent triggered.
l
0x0F - Automatic release completed.
Info
While booting, status LED will be solid blue / red.
kFLT
See your optional controller manual (input registers and status).