Robotiq Hand-E Gripper - Instruction Manual
7.2. Periodic inspection
Maintenance Interval Tools You Need Parts You Need
Monthly
l 4 mm hex key
l Dry tissue or towel
l Medium strength thread locker
None (unless damage is detected)
Info
Always turn off robot and Gripper power supply before performing maintenance operations on the Gripper.
1. Remove and clean the Gripper following instructions in the Gripper cleaning section
2. Inspect the Gripper
l Finger movement must be symmetric and fluid; test opening and closing of the Gripper:
l Finger or fingertip wear must not affect gripping, if wear is visible and affects movement, change accordingly (refer to the
Gripper cleaning section)
l Check for any collision damage, if damage is visible, contact support@robotiq.com
l Check for any sign of wear on the Gripper chassis; if wear is present and may affect the Gripper, contact
support@robotiq.com
3. Put back in place according to the instructions from the Gripper cleaning section
82