Robustel GoRugged R3000 Lite User Guide
RT_UG_R3000 Lite_v.1.4.1 15.11.2016 115 / 135
Confidential
4.2.2 SMS Remote Status Reading
R3000 Lite supports remote control via SMS. Users can use following commands to get the status of R3000 Lite,
cannot set new parameters of R3000 Lite at present.
An SMS command has following structure:
Password:cmd1,a,b,c;cmd2,d,e,f;cmd3,g,h,i;...;cmdn,j,k,n
SMS command Explanation:
1. Password: SMS control password is configured at Basic‐>SMS Control‐>Password, which is an optional
parameter.
a) When there is no password, SMS command has following structure: cmd1;cmd2;cmd3;…;cmdn
b) When there is a password, SMS command has following structure: Password:cmd1;cmd2;cmd3;…;cmdn
2. cmd1, cmd2, cmd3 to Cmdn, which are command identification number 0001 – 0010.
3. a, b, c to n, which are command parameters.
4. The semicolon character (‘;’) is used to separate more than one commands packed in a single SMS.
5. E.g., 1234:0001
In this command, password is 1234, 0001 is the command to reset R3000 Lite.