Robustel GoRugged R3000 Lite User Guide
RT_UG_R3000 Lite_v.1.4.1 15.11.2016 90 / 135
Confidential
VACM @ SNMP
Item
Description
Default
Readwrite
Select the access rights from “Readonly” and “ReadWrite”.
Readonly
Network
Define the network from which is allowed to access. E.g. 172.16.0.0.
Null
Community
Enter the community name.
Null
MIBview
Select from “none”, “system” and “all”
none
Trap @ SNMP
Item
Description
Default
Enable SNMP Trap
Click to enable SNMP Trap feature.
Disable
Version
Select from “SNMPv1”, “SNMPv2” and “SNMPv3”.
SNMPv2
Server Address
Enter SNMP servers IP address.
Null
Port
Enter SNMP servers port number
0
Name
Enter SNMP servers name.
Null
Download MIB Moudles File @ SNMP
Item
Description
Download MIB Moudles
File
Click to download the MIB Moudles File

Table of Contents