Rockwell Automation Publication 750-TG100B-EN-P - June 2019 279
Power Bay Components Chapter 9
Install the Torque Accuracy Module
Install the torque accuracy module in the reverse order of removal.
When installing the fiber-optic cable:
1. Without bending the cable to a radius less than 50 mm (2 in.), fully insert
the fiber-optic cable into the transceiver.
2. Insert the transceiver and fiber-optic cable into the port on the board, until
you hear an audible ‘click.
DC Bus Conditioner
Replacement
Replace the DC bus conditioner with kit catalog number
20-750-MDCBUS-COND.
Remove the DC Bus Conditioner
Follow these steps to remove the DC bus conditioner.
1. Review the Product Advisories on page 14
.
2. Remove power from the system. See Remove Power from the System on
page 15
.
3. Open the corresponding power bay enclosure door.
4. If present, remove the guards from the enclosure. See Guard Removal on
page 235
.
IMPORTANT
Minimum inside bend radius for fiber-optic cable is 50 mm
(2 in.). Any bends with a shorter inside radius can
permanently damage the fiber-optic cable. Signal
attenuation increases as inside bend radius is decreased.
50 mm
(2 in.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation PowerFlex 755TL and is the answer not in the manual?

Rockwell Automation PowerFlex 755TL Specifications

General IconGeneral
BrandRockwell Automation
ModelPowerFlex 755TL
CategoryDC Drives
LanguageEnglish

Related product manuals