Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
342User Manual 1173.9240.02 ─ 17
Example:
INST:SEL ADEM
Activates analog demodulator.
CALC:FEED 'XTIM:FM'
Selects the display of the FM signal.
Table 11-6: <Evaluation> parameter values for the AnalogDemod application
Parameter Evaluation
'XTIM:AM:RELative' AM Time Domain
'XTIM:AM:RELative:AFSPectrum' AM Spectrum
'XTIM:FM' FM Time Domain
'XTIM:FM:AFSPectrum' FM Spectrum
'XTIM:PM' PM Time Domain
'XTIM:PM:AFSPectrum' PM Spectrum
'XTIM:SPECtrum' RF Spectrum
'XTIM:AM'
'XTIM:RFPower'
RF Time Domain (= RF power)
'XTIM:AMSummary'
'XTIM:AMSummary:RELative'
'XTIM:FMSummary'
'XTIM:FMSummary:RELative'
'XTIM:PMSummary'
'XTIM:PMSummary:RELative'
'XTIM:SUMMary'
Result summary
11.11 Programming Example
In this example we will configure and perform an analog demodulation measurement to
demonstrate the remote control commands.
Signal generator settings (e.g. R&S SMU):
Frequency: 500 MHz
Level: -10 dBm
Modulation: FM
Modulation frequency: 10 kHz
Frequency deviation: 50 kHz
//-----------Preparing the measurement ------------
*RST