Analysis
R&S
®
FSW-K7
142User Manual 1173.9240.02 ─ 17
Search Next Minimum
Sets the selected marker/delta marker to the next (higher) minimum of the selected
trace. If no marker is active, marker 1 is activated.
Remote command:
CALCulate<n>:MARKer<m>:MINimum:NEXT on page 310
CALCulate<n>:DELTamarker<m>:MINimum:NEXT on page 311
6.5 Marker Function Configuration
Special marker functions can be selected via the "Marker Function" dialog box.
To display this dialog box, do one of the following:
Press the MKR FUNC key, then select the "Select Marker Function" softkey.
In the "Overview", select "Analysis", and switch to the vertical "Marker Function
Config" tab.
Not all marker functions are available for all evaluations. The following table indicates
which functions are available for which evaluations.
Evaluation n dB down Phase Noise Reference Fixed
AF time - - X
AF spectrum X X X
RF time X - X
RF spectrum X X X
For details on the special marker functions see the R&S FSW User Manual.