EasyManua.ls Logo

Rosemount 2130 - Maintenance; Troubleshooting

Rosemount 2130
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Manual
00809-0100-4130, Rev AA
May 2009
3-3
Rosemount 2130
MAINTENANCE
NOTE
Only use a soft brush for cleaning.
TROUBLESHOOTING If there is a malfunction, see Table 3-1 for information on possible causes.
Table 3-1.
Troubleshooting Chart
SPARE PARTS See “Spare Parts and Accessories” on page A-14.
2130/FIG18A, FIG18B, FIG18C.EPS
2130_52AA.EPS
Fault Symptom/Indication Action/Solution
Does not
switch
• No LED; no power • Check the power supply; (check load on
direct load switching electronics model)
• LED flashing • See “LED Indication” on page 2-5
• Fork is damaged • Replace the 2130
• Thick encrustation
on the forks
• Clean the fork with care
• 5 second delay when
changing mode/delay
• This is normal – wait 5 seconds
Incorrect
switching
• Dry = On, Wet = On
set correctly
• Set the correct mode on the electronics
cassette
Faulty
switching
• Turbulence • Set a longer switching time delay
• Excessive electrical noise • Suppress the cause of the interference
• Cassette has been fitted
from another Rosemount
2130
• Fit the factory supplied cassette
and then calibrate.
(See “Replacement and Calibration of
Electronic Cassettes” on page 3-4.)

Table of Contents