57
AA
An actuator fitted with the interrupter
timer and set as the example shown in
these instructions would operate at:
Rated speed from full Open to 25%
Open.
1
/
6
rated speed from 25% Open to Fully
Closed and from Fully Closed to 25%
Open.
Rated speed from 25% Open to Fully
Open.
With a Folomatic option fitted and
the Interrupter Timer enabled, the
Folomatic Motion Inhibit Timer must
be adjusted to the same time as that
set for the Interrupter Timer “contactor
off”.
Failure to do so will cause the actuator
response to defer to the lower time
which may cause control or process
problems.
For “ON” and “OFF” times in excess of
99 seconds apply to Rotork.
The default setting for Setting Tool
Local Control is [OF]
Control Disabled
.
To enable Setting Tool Control press the
+
or
-
key to select [On].
PRESS THE KEY.
The displayed option will flash (stored)
indicating that it has been set.
With the red control selector in Local,
the Setting Tool control keys are active
(refer to page 12).
Local Setting Tool Control Enabled
Vandal resistant actuators ONLY
(red/black selectors not supplied).
For control, the selection of [O
r
]
Vandal
Resist
is as follows:
[O
n]
Local Only
.
[OF]
Control Disabled
.
[
rE]
Remote Only
.
The default setting for this
protection option is disabled [OF].
When disabled it is important
that the actuator is not manually
operated during a power failure
if the battery is low as changes in
position cannot be tracked - refer
to page 6 for battery level status
display. Should this occur the
limits must be reset before electric
operation takes place- refer to LC/
LO page 27. Locking the hand auto
lever can prevent manual operation
- refer to Section 3.1, page 3.
The protection may be enabled by using
the
+
or
-
key to select [On]
PRESS THE KEY.
The displayed option will flash (stored)
indicating that it has been set.
When protection is enabled, on power
up if a low battery is detected, the
actuator will inhibit electrical operation
and display Power Loss Inhibit via
actuator alarm display (refer to page 5)
and the monitor relay will de-energise.
Limits must reset and the battery
replaced – refer to page 67.
Press the
k key to display:
[OH]
Close Colour
.
Example
Note
9.14
Setting Tool
Local Control [Or]
9.15
Inhibit Operation
After Power Loss [OS]
I-R Tool Control
On
Power Loss
Inhibit : Off

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the rotork IQT and is the answer not in the manual?

rotork IQT Specifications

General IconGeneral
Quarter-turnYes
Housing MaterialAluminum alloy
Torque Range10 Nm to 3000 Nm
Multi-turnYes
LinearYes
Ingress ProtectionIP68
Communication ProtocolsModbus, Profibus, Foundation Fieldbus
Operating Temperature+70°C
Local Controlslocal pushbuttons
Control ModesModulating
DisplayLCD
TypeIntelligent Electric Actuator