Troubleshooting
Samsung Electronics 231
Action
Solution
- Change the wire to new one
How to check the Comm. IC
Action Result
Check wiring to F1,F2 terminal block OK
Comm. IC check OK
Check ODU PBA setting OK
Check Other error occurrence OK
Wiring broken check NG – middle of the F1 wire was broken
Measurement Method
Measure the No.5- No.6 / No.5- No.7 / No.5- No.8 Pin resistance
Judgment
- Normal : Each resistance value = in hundreds Ω ~ to hundreds of kΩ.
- Defective : One or both are low with tens of Ω
One or both of them is open
4-4-5 Case study – E201 (Communication error between indoor & outdoor unit) (cont.)