● Symptom / Cause :
1. Magenta OPC motor is broken.
2. The relative connector is disconnected.
3. Deve joint board and main board are defective.
4. Even it was ready, it does not working.
5. After starting, it is not reached at ready state.
● Troubleshooting method :
1. Enter the diagnostic mode. Select the test routine.
Execute the Magenta OPC BLDC motor test. If the
2. If the problem persists, remove the rear cover.
3. Open the Main board plate.
4. Remove the Magenta OPC BLDC motor and one
MCK
6. If the motor works, check the connection
7. Replace the Deve joint board or engine board.
● Replacement part
- JC31-00123A (MOTOR BLDC)
- JC92-02152A (DEVE-JOINT)
- JC92-02129A : PBA-ENGINE (CLX-9350ND)