● Symptom / Cause :
The fuser unit is at the end of its life (150K).
● Troubleshooting method :
1. Turn the machine off and turn it on again.
2. Print the supply information report and check the fu
3. Replace the fuser unit.
● Replacement part
- JC91-00931A : FUSER (220V)
- JC91-00930A : FUSER (110V)
Service Manual
CLX-9250/9350 series
7-