Code :
C6-1311
Error message
:
Fuser unit is not ins
t
Symptom / Cause :
The fuser unit is not installed properly.
The connector of fuser unit is not connected properly.
Troubleshooting method :
1. Turn the machine off.
2. Open the side door and check if the fuser unit is ins
2.
Open
the
side
door
and
check
if
the
fuser
unit
is
ins
3. If the fuser unit is installed, check the following :
A
. Check if the both handle lockers are locked prope
B. Check the draw connector between the fuser unit
C. Check if the draw connector is disconnected.
4. Remove the fuser unit and re-install it.
5. Turn the machine on.
6. If the problem persists, replace the fuser unit.
Replacement part
- JC91-00931A : FUSER (220V)
- JC91-00930A : FUSER (110V)