● Code :
S1-5221
● Error message
System Failure #S1
● Symptom / Cause :
Communication error has occurred.
● Troubleshooting method :
1. Did you replace the HDD / Video board?
Yes : Update the firmware for the new board.
2. Does the problem occur after updating the firmwar
. Print the configuration report and check the fi
B. If all software versions are not normal, updat
C. If the problem persists, replace the defective
3. Check the connection between HUB board and Vide
No : Reconnect or replace the cable.
Yes : Replace the HUB board.
4. If the problem persists, replace the Video board.
● Re
- JC92-02150A : PBA-MAIN (CLX-9350ND)
- JC92-02235A : PBA-MAIN (CLX-9250ND)
Service Manual
CLX-9250/9350 series
7-1
-5221 : Turn off then on.
evice. (HDD / Video board )