Unit 4: Standard Command Codes
E/Pro Programming Reference
4-108 PN: 9001096E
SERIAL INTERFACE
FUNCTION
Specifies the setting of the serial interface.
FORMAT
<ESC>I2abcde
a = BAUD rate:
0 = 9600bps
1 = 19200bps
2 = 38400bps
3 = 57600bps
b=Data bit
0 = 8bit
1 = 7bit
c=Parity
0 = No parity
1 = Odd
2 = Even
d = Stop bit
0 = 1bit
1 = 2bit
e=Control
0 = READY/BUSY control (Single item buffer)
1 = READY/BUSY control (Multi item buffer)
2 = XON/XOFF
3 = Driver protocol
4 = Status 3
Place this command between <ESC>A start code and <Z> stop code..
EXAMPLE
<ESC>A
<ESC>I210003
<ESC>Z
OUTPUT
This command does not result in printer output.
NOTES
The set parameter will become valid after rebooting.