Unit 4: Standard Command Codes
E/Pro Programming Reference
4-114 PN: 9001096E
USER DOWNLOAD
FUNCTION
Allows the user to define custom Protocol Command codes.
FORMAT
<ESC>LDa,
a = Replacement character for STX
b = Replacement character for ETX
c = Replacement character for ESC
d = Replacement character for ENQ
e = Replacement character for CAN
f = Replacement character for NUL
g = Replacement character for OFFLINE
h = Auto-Online. Printer powers up in the online mode.
0: Yes
1: No
i = Zero Slash. Places a slash through the “0” character.
0: Yes
1: No
j = Hexa-decimal character for Euro-character
Place immediately following <ESC>A within its own stream.
EXAMPLE
<ESC>A
<ESC>LD,{,},%,#,&,*,~,0,0,D5
<ESC>Z
OUTPUT
A Protocol Command code status label will be printed as a result of the successful download
of a custom set of Protocol Command codes.
(4-61)
NOTES
Commas must be used to separate the parameters. If a parameter is omitted between two commas,
the default Non-Standard Protocol Command codes for that parameter will be used. If more or less
than 10 commas is included in the command, the entire command sequence will be ignored. If a
combination of characters are outside the hexadecimal range, the entire command sequence will be
ignored.
Downloading Auto Online and Zero Slash settings will overwrite the values selected using the LCD
panel. If these settings are changed using the LCD panel, they will overwrite any previously
downloaded settings.