Unit 5: Optional Command Codes
E/Pro Programming Reference
5-12 PN: 9001096E
FORMAT/FIELD, RECALL
FUNCTION
To recall a field from a stored format and place new data in the field.
FORMAT
<ESC>YR,aa<ESC>/D,bb,cc....c
aa = Format number to be recalled (01 to 99)
bb = Field number to be recalled (01 to 99)
cc...c = Data to placed in the recalled field
Place immediately following the <ESC>CC Slot Select command.
EXAMPLE
<ESC>A
<ESC>CC1
<ESC>YR,02<ESC>/D,01,TWO FIELDS OF <ESC>/D,02,VARIABLE DATA
<ESC>Q1<ESC>Z
OUTPUT
(5-4)
NOTES
This command requires the Expanded Memory option.
Only one format can be recalled at a time. However, multiple fields can be recalled from the same
format.
The number of data characters contained in the “cc...c” field cannot exceed the value designated in the
<ESC>/N Field Store command. If it does, the data will be truncated to fit the field length defined in the
store command.