Unit 3: Code Quick Reference
E/Pro Programming Reference
3-10 PN: 9001096E
CSa Print Speed Selection. Specifies a unique print speed in in./sec. through software for a
particular label.
a = Speed Range
CTa Cut number unit. Cuts label at a specified interval in a print job.
a = Number of labels between each cut: Quantity range: 0 to 9999.
Dabbcccn Barcode, Ratio 1:2. Prints a 1:3 ratio barcode.
a = Barcode Type
0: NW-7
1: CODE39
2: Interleaved 2 of 5
3: JAN/EAN-13 (fixed ratio)
4: JAN/EAN-8 (fixed ratio)
5: Industrial 2 of 5
6: Matrix 2 of 5
H: UPC-A (fixed ratio)
b = Narrow bar width (01 to 12 dots)
c = Barcode height (001 to 999 dots)
n = Barcode print data
dn...n Barcode, Human Readable Information (HRI). Specifies the character type of human
readable information of barcode. Used in conjunction with the preceding <ESC>D.
d = Character type specification
XU
XS
XM
XB
XL
OA
OB
HRI data
n = HRI print data
DCxx...x Data Matrix. Print Data. Prints data using Data Matrix format specified in BX Data Format
command.
xx...x = Data to be printed. Cannot exceed 500 characters.
DIa Interface. Specifies the interface used to connect with a host.
a = Interface
0: USB/Wireless LAN
1: RS-232C or LAN
2: Keypad
COMMAND QUICK REFERENCE
INSTRUCTION DESCRIPTION