Starting Up the Printer
59
Mobile printer PW208NX/PW208mNX
Receiving Level (PW208NX only)
Printing > Advanced > Calibrate > Gap Sensor > Receiving Level
Adjust the Gap sensor receiving level.
Receive : Initial value : 62
: Setting range : 0 to 127
Slice Level (PW208NX only)
Printing > Advanced > Calibrate > Gap Sensor > Slice Level
Adjust the Gap sensor slice level.
Slice level : Initial setting : 0.0 V(Auto)
: Setting options : 0.0 V to 3.3 V
■ Slice Level Adjustment of the Gap Sensor
1. Use the following formula to calculate the slice level.
(High value – Low value) ×0.7 + Low value = Slice Level
2. Select Calibrate > Gap Sensor > Slice Level.
3. Press the
button to change the slice level. Adjust the slice level so that it
becomes the level calculated in step 1.
4. Press the
button to decide the slice level.