Placing the milk container in the cooling unit
Reordering a decalcification cartridge
Ending the descaling process and restarting the machine
7.1.6 Disposing of decalcification cartridges
The decalcification cartridge is made of plastic and cannot be disposed of with household waste after a proper des-
caling process. The decalcification cartridge must be completely emptied and rinsed with water after descaling.
7.2 External water filter
14) ► Place milk container with cooled milk into the cooling unit.
► Select the [>] field for the next step.
Instruction, reorder a decalcification cartridge.
15) The article number appears in the user interface.
► Reorder a cartridge from your service partner for the next descaling process.
► Select the [>] field for the next step.
Restarting the machine
15a) The descaling programme closes.
Restarting the machine
Ready for use, the user interface appears.
The last executed descaling process is shown in the service menu under "Maintenance".
NOTE
A descaling process which was not run properly or was incomplete does not com-
pletely empty the decalcification cartridge.
Run the descaling process properly to the end.
Do not disconnect the machine from the mains before descaling is complete.
If descaling is interrupted, the decalcification cartridge must be disposed of as hazardous
waste in line with the local regulations.
The external water filter must be replaced by an authorised service partner/service technician after the programmed
number of litres is reached.
The "Water quality" supplementary instructions include information on recording the water values and using filter
equipment. The supplementary instructions can be requested from Schaerer AG or downloaded directly from the
MediaCentre on the website (http://www.schaerer.com/member).