IO-Link Data Dictionary SCPSi series
21.10.01.00065/02 29.08.2014
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
79 0x004F dpy 1 byte 0 - 1 rw 0
0 = standard
1 = rotated
76 0x004C Eco 1 byte 0 - 1 rw 0
0 = off
1 = on
68 0x0044 ctr 1 byte 0 - 2 rw 1
0 = not active (off)
1 = active (on)
2 = active with supervision (onS)
78 0x004E dCS 1 byte 0 - 1 rw 0
0 = off
1 = on
100 0x0064 H-1 2 bytes 998 >= H1 >= (H2+h1) rw 750 Unit: 1 mbar
101 0x0065 h-1 2 bytes (H1-H2 >= h1 > 10 rw 150 Unit: 1 mbar
102 0x0066 H-2 2 bytes (H1-h1 >= H2 >= (h2+2) rw 550 Unit: 1 mbar
103 0x0067 h-2 2 bytes (H2-2) >= h2 >= 10 rw 10 Unit: 1 mbar
106 0x006A tbL 2 bytes 100 - 9999 rw 200 Unit: 1 ms
107 0x006B t-1 2 bytes 0, 10 - 9999 rw 2000 Unit: 1 ms
108 0x006C -L- 2 bytes 1 - 999 rw 250 Unit: 1 mbar/sec
180 0x00B4 1 byte 0 - 2 rw 1
181 0x00B5 1 byte 0 - 1 rw 0
182 0x00B6 2 bytes 998 >= H1 >= (H2+h1) rw 750
183 0x00B7 2 bytes (H1-H2 >= h1 > 10 rw 150
184 0x00B8 2 bytes (H1-h1 >= H2 >= (h2+2) rw 550
185 0x00B9 2 bytes (H2-2) >= h2 >= 10 rw 10
186 0x00BA 2 bytes 100 - 9999 rw 200
187 0x00BB 2 bytes 0, 10 - 9999 rw 2000
188 0x00BC 2 bytes 1 - 999 rw 250
200 0x00C8 1 byte 0 - 2 rw 1
201 0x00C9 1 byte 0 - 1 rw 0
202 0x00CA 2 bytes 998 >= H1 >= (H2+h1) rw 750
203 0x00CB 2 bytes (H1-H2 >= h1 > 10 rw 150
Hysteresis h1
Setpoint H1
Disable continuous suction
Setpoint H2
Hysteresis h2
Display rotation
Setpoint H2
Hysteresis h2
Hysteresis h1
Permissible leakage rate
Permissible leakage rate
Production Setup - Profile P1
Air saving function
Disable continuous suction
Setpoint H1
Hysteresis h1
Profile P-2
(selected by PD Out 0 - Profile-Set = 2)
Setpoint H1
Eco-Mode
Production Setup - Profile P0
Duration automatic blow
Permissible evacuation time
Air saving function
Disable continuous suction
Duration automatic blow
Profile P-1
(selected by PD Out 0 - Profile-Set = 1)
Permissible evacuation time
Production Setup - Profile P2
Air saving function
J. Schmalz GmbH
4 of 11 SCPSi Data Dictionary