IO-Link Data Dictionary SCPSi series
21.10.01.00065/02 29.08.2014
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
204 0x00CC 2 bytes (H1-h1 >= H2 >= (h2+2) rw 550
205 0x00CD 2 bytes (H2-2) >= h2 >= 10 rw 10
206 0x00CE 2 bytes 100 - 9999 rw 200
207 0x00CF 2 bytes 0, 10 - 9999 rw 2000
208 0x00D0 2 bytes 1 - 999 rw 250
220 0x00DC 1 byte 0 - 2 rw 1
221 0x00DD 1 byte 0 - 1 rw 0
222 0x00DE 2 bytes 998 >= H1 >= (H2+h1) rw 750
223 0x00DF 2 bytes (H1-H2 >= h1 > 10 rw 150
224 0x00E0 2 bytes (H1-h1 >= H2 >= (h2+2) rw 550
225 0x00E1 2 bytes (H2-2) >= h2 >= 10 rw 10
226 0x00E2 2 bytes 100 - 9999 rw 200
227 0x00E3 2 bytes 0, 10 - 9999 rw 2000
228 0x00E4 2 bytes 1 - 999 rw 250
2 0x0002 1 byte wo
0x05 (dec 5): Force upload of parameter data into the master
0x82 (dec 130): Restore device parameters to factory defaults
0xA4 (dec 164): Clear diagnostic buffer
0xA5 (dec 165): Calibrate vacuum sensor
120 0x0078 CAL 1 byte 1 wo
1 = Calibrate vacuum sensor
(can also be executed by switching PD Out 0 Bits 2 and 3 simultaneously
from 0 to 1)
123 0x007B rES 1 byte 1 wo 1 = Restore to factory defaults
System command
Calibrate vacuum sensor
Disable continuous suction
Profile P-3
(selected by PD Out 0 - Profile-Set = 3)
Hysteresis h1
Permissible leakage rate
Hysteresis h2
Setpoint H2
Duration automatic blow
Permissible evacuation time
Restore to factory defaults
Hysteresis h2
Setpoint H2
Setpoint H1
Permissible leakage rate
Air saving function
Duration automatic blow
Commands
Permissible evacuation time
Production Setup - Profile P3