Assembly
14.00 | SRU-plus 20 - 60 | Assembly and Operating Manual | en | 389443 47
1. Connect magnetic switch and secure cable, see sensor
assembly and operating manual.
2. Actuate air connection A (4).
ð Pinion (2) swivels towards the end position.
3. Slide the first magnetic switch (6) into a groove (5).
Or: Screw magnetic switch (6) into a groove (5) (1).
4. Adjust magnetic switch (6), see Sensor Assembly and
Operating Manual.
5. Tighten set screw (8).
ð Tightening torque: 10 Nm
6. Ventilate air connection A (4).
7. Actuate air connection B (3).
ð Pinion (2) swivels in the other end position.
8. Slide the second magnetic switch (6) into the other groove
(5).
Or: Screw magnetic switch (6) into the other groove (5).
9. Adjust magnetic switch (6), see Sensor Assembly and
Operating Manual.
10. Tighten set screw (8).
ð Tightening torque: 10 Nm
11. Check switching positions, set again if necessary.
Center position
variant
Rotate unit in the center position and mount sensor analogously.