Assembly
48 14.00 | SRU-plus 20 - 60 | Assembly and Operating Manual | en | 389443
5.5.4 Mounting inductive proximity switch IN 80
CAUTION
Material damage to the product or sensor possible!
If the fast clamping sleeve is inserted too far into the sensor
bracket, the switch cam and the sensor may collide during
swiveling.
l
Do not insert the fast clamping sleeve too far into the sensor
bracket.
l
Pay attention to the distance between fast clamping sleeve
and switch cam.
With the sensors, three positions can be queried:
l
End position "A"
l
Center position "M"
l
End position "B"
The positions are monitored with switch cams (7/7.1). The switch
cams are of different lengths. Observe the following when setting
the sensors:
l
Size 20: Use the short switch cams to set the end positions A
and B and the longer switch cam for center position M.
l
from size 25: Use the longer switch cams to set the end positions
A and B and the short switch cam for center position M.
The following assembly steps are the same for all three positions:
1. Screw cam disk (6) onto pinion.
ð Use centering sleeves from the accessory kit.
ð Place seal from the accessory kit between cam disk (6)
and pinion.