Assembly
14.00 | SRU-plus 20 - 60 | Assembly and Operating Manual | en | 389443 49
ð IMPORTANT!For the variant with electrical
feedthrough(EDF), a seal must additionally be placed
between cam disk and distributor plate.
2. Connect sensor and secure cable, see sensor assembly and
operating manual.
3. Remove the corresponding cover disk on the housing (5).
4. Screw bracket (9, 10, 11) into the countersink of the housing
(5) provided until the clamping sleeve (4) can still be turned.
5. Turn swivel unit counter-clockwise to the corresponding end
stop or the center position.
Or with movable switch cams: Loosen set-screw of the switch
cam (7/7.1) and push switch cam (7/7.1) until it is positioned at
the height of the corresponding clamping sleeve (4).
6. Turn swivel unit back to the output position and secure the
switch cam (7/7.1).
7. Turn swivel unit counter-clockwise to the corresponding end
stop or the center position.
8. Insert sensor into the clamping sleeve (4) up to stop.
9. Unscrew clamping sleeve (4) until the sensor switches.
10. Tighten the screw (3) until the clamping sleeve (4) can no
longer be turned.
ð Screw(3) jams the clamping sleeve(4) and at the same
time secures the bracket(9, 10, 11).
11. Tighten the attachment screws (1), until the sensor is fixed in
place.
12. Check switching positions, reset if necessary.